FS3 – Thermal Tire Protector

The tyre protectors is made of flame retardant materials with high resistance to flames and high temperatures. It is an accessory that protects and minimizes the risk of the tires reaching their ignition point, preventing the vehicle from being set on fire.
FLAME RETARDANT TYRE PROTECTORS FS 3

FIREPROOF TIRE PROTECTORS FS3

Connections sewn with thread and Kevlar tape.
4-layer flame retardant fabric.
Grip and positioning handles.

Technical characteristics

Conformities: European General Product Safety Directives 2001/95/CE, Royal Decree 1801/2003 and Directives on minimum health and safety requirements for the use of work equipment by workers, Directive 89/655/CEE, Directive 95/63/CEE, Directive 2001/45/CE and Royal Decree 1215/1997.

Certification of the fabric: The set of layers that make up the fabric has been certified by a notified body accredited by ENAC and in accordance with the UNE EN ISO 11612 and EN 469/A1 standards, according to:

  • EN ISO 15025 
  • ISO 9151 
  • EN ISO 6942 
  • ISO 12127-1
  • ISO 17493 
  • EN ISO 13934-1
  • EN ISO 13937-2 
  • EN ISO 13935-2

 Accredited Notified Body Number: 0161
Test report number: 2017 EP3190

Materials

1st and 2nd outer layer: with special protection against radiant heat, 3rd and 4th inner layer: with special thermal protection.

Dimensions and weight for light vehicle:

  • (D)800mm X (H max) 800mm x (W)230mm.
  • Carrying bag: (L)750mm X (H)250mm x (W)600mm
  • Unit weight: 2 kg.

Dimensions and weight for heavy vehicle:

  • (D)1200mm X (H max) 1200mm x (W)400mm
  • Carrying bag: (L)750mm X (H)250mm x (W)600mm
  • Unit weight: 2.5 kg.

Performance

Indoor radiant and convective heat protection against flames with a maximum power of up to 600 kW, a medium flame speed of up to 20 km/h and a minimum distance of 1.5 m from the front of the shelter.

 Indoor radiant and convective heat protection against flames up to 10.5 m wide with a maximum power up to 80 MW, without forced ventilation and at a minimum distance of 2 m from the front of the shelter.

Performance level obtained in EN ISO 11612 fabric certification:

  • A1 (EN ISO 15025, Procedure A)
  • A2 (EN ISO 15025, Procedure B)
  • B2 (ISO 9151)
  • C4 (EN ISO 6942, Method B)
  • F3 (ISO 12127-1)
  • COMPLIES (ISO 17493)
  • COMPLIES (EN ISO 13934-1)
  • COMPLIES (EN ISO 13937-2)
  • COMPLIES (EN ISO 13935-2)

Performance level obtained in the EN 469/A1 fabric certification: 

  • LEVEL 2 (ISO 9151)
  • LEVEL 2 (EN ISO 6942, Method B)
  • COMPLIES (ISO 17493)
  • COMPLIES (EN ISO 13934-1)
  • COMPLIES (EN ISO 13937-2)
  • COMPLIES (EN ISO 13935-2)

ISK Fire Survival

Fire Intervention in Forest

Despite being an indispensable element in the comprehensive safety kit, to deal with risk situations due to entrapment with pumper vehicles, its different of features combined with its effectiveness, make the device an element with a variety of applications in the different firefighting and rescue services.
It is used in interventions related to the protection of people or property, that may be threatened by fire, as well as an element of special interest to help establish and promote the protection, extinction and safety of personnel involved in all those operations of extinction and rescue that imply an imminent risk or threat to combatant personnel. This, combined with its adaptation ability to the different sources of water supply (fixed-mobile), coming from boost systems and firefighting networks, such as extinguishing vehicles, motor pumps, etc; make it a device with applications in different sectors and users.

Forest fire protection for fire man